PTFE Redistributor
Anti-channeling redistributor, DN 80 to DN 600
PTFE redistributor clamped between two column sections to prevent channeling — DN 80 to DN 600 in eight catalogue sizes, fitted without any gasket.
| Product type | PTFE redistributor — anti-channeling column internal |
|---|---|
| Material | PTFE |
| Column size range | DN 80 to DN 600 |
| Central opening (d) | 55 mm to 420 mm, size dependent |
| Height (L) | 20 mm to 30 mm, size dependent |
| Fitting | Clamped between two column sections, without using any gasket |
| Pressure rating | Not published on the catalogue page — confirm with us for your duty |
| Temperature rating | Not published on the catalogue page — confirm with us for your duty |
Product overview
What it does, and where it fits.
Liquid running down a packed column does not stay evenly spread. It migrates to the wall, where it finds the path of least resistance and runs straight past the packing — channeling. The centre of the bed goes dry, the wall film does no separating work, and the column quietly stops performing to its rating. The catalogue puts the item's purpose plainly: the PTFE redistributor is used to prevent channeling in a column.
It works by interrupting that wall film. Fitted at the joint between two column sections, the redistributor catches the liquid running down the wall and returns it to the centre of the bed below, so the next section starts with the flow spread across its full area again. On a tall column, one is fitted every few sections — the taller the packed height, the more times the flow needs collecting and re-spreading.
The catalogue is specific about the fit: it can be clamped between two column sections without using any gasket. The PTFE seats directly on the glass, so the redistributor adds nothing to the joint stack and needs no separate sealing element.
Eight references cover DN 80 to DN 600 — the widest span in this range. DN is the column diameter, d the central opening the redistributed liquid falls through, and L the height of the unit, 20 mm on the small sizes rising to 30 mm at DN 450 and DN 600.
Features
Built into every unit.
- Prevents channeling — collects the wall film and returns it to the centre of the bed
- Clamped between two column sections without using any gasket, per the catalogue
- Virgin PTFE construction throughout
- DN 80 to DN 600 in eight catalogue references — the widest range in this category
- Central opening d from 55 mm at DN 80 to 420 mm at DN 600
- Height L 20 mm to 30 mm, stepped with column size
Benefits
Why it earns its place in the line.
- Restores even liquid distribution, so the packing below works across its full area
- No gasket in the joint — one fewer consumable and one fewer leak path
- Virgin PTFE — inert to almost every process medium a glass column will see
- Clamped between two components, so no adhesive and no fixings enter the column
- Will not soften, swell or embrittle across the working range of a borosilicate column
- Non-wetting surface sheds liquid instead of holding it, so nothing pools on the plate
Applications & industries
Where it is specified.
Typical applications
- Breaking up wall flow part-way down a packed fractionating column
- Tall packed sections where liquid has room to migrate to the wall
- Absorption and scrubbing columns running at low liquid rates
- Solvent recovery columns that must hold their separation over a long run
- Any column being extended, where a new section joint is an opportunity to redistribute
Industries served
- Chemical processing
- Pharmaceutical
- Fine chemicals & dyes
- Distillation & solvent recovery
- Water & effluent treatment
- Agrochemicals
- Research & pilot plant
Technical data
Specification for PTFE Redistributor.
Figures below are for this product only — every item in the range carries its own dimension table.
| Product type | PTFE redistributor — anti-channeling column internal |
|---|---|
| Material | PTFE |
| Column size range | DN 80 to DN 600 |
| Central opening (d) | 55 mm to 420 mm, size dependent |
| Height (L) | 20 mm to 30 mm, size dependent |
| Fitting | Clamped between two column sections, without using any gasket |
| Pressure rating | Not published on the catalogue page — confirm with us for your duty |
| Temperature rating | Not published on the catalogue page — confirm with us for your duty |
| Catalogue reference | ATL series, e.g. ATL 12 = DN 300 |
| Cat. Ref. | DN | d | L |
|---|---|---|---|
| ATL 3 | 80 | 55 | 20 |
| ATL 4 | 100 | 80 | 20 |
| ATL 6 | 150 | 100 | 20 |
| ATL 9 | 225 | 175 | 22 |
| ATL 12 | 300 | 215 | 25 |
| ATL 16 | 400 | 315 | 25 |
| ATL 18 | 450 | 365 | 30 |
| ATL 24 | 600 | 420 | 30 |
All dimensions in mm, transcribed exactly from the catalogue page. The catalogue states: “DN refers the nominal diameter of the column.” DN is the column this item is sized for, not a dimension of the part. d is the central opening and L the height of the unit.
FAQ
Questions we are asked about this item.
Liquid running down a packed column drifts to the wall and runs past the packing instead of through it. The centre of the bed dries out, the wall film does no separating work, and the column stops meeting its rating. The redistributor collects that wall flow and returns it to the centre.
No. The catalogue states it can be clamped between two column sections without using any gasket — the PTFE seats directly on the glass.
That depends on packed height, packing type and liquid rate rather than on anything printed in the catalogue. Send us the column arrangement and duty and we will advise on the spacing.
The central opening the redistributed liquid falls through. DN is the nominal diameter of the column and L is the height of the unit.
Enquiry
Tell us your line size — we'll confirm the spec.
Send the bore, the media, the temperature and pressure, and the flange standard you work to. Drawings and custom sizes welcome.
Not sure which spec fits your process?
Send your requirement — media, temperature, pressure, dimensions — and we'll recommend the right product or fabricate it.
Talk to an engineer