Spacer
Glass spacer for small length increments, DN 15 to DN 50
Short glass spacer used to make up small increments in line length — DN 15 to DN 50 in 5, 15, 25 and 50 mm.
| Product type | Glass spacer |
|---|---|
| Material | Borosilicate 3.3 |
| Nominal bore range | DN 15 to DN 50 |
| End connection | Beaded pipe ends with backing flanges and PTFE-envelope gaskets |
| Flange drilling | See the drilling table — BS 10 Table E, BS 10 Table F and ASA drilling available |
| Pressure rating | Not published on the component datasheet — confirm with us for your duty |
| Temperature rating | Not published on the component datasheet — confirm with us for your duty |
| Dimensional standard | As per the Lata Scientific component datasheet |
Product overview
What it does, and where it fits.
When a glass line is set out, the standard section lengths rarely add up to the exact distance between two fixed points. The spacer closes that gap. It is supplied in four lengths — 5, 15, 25 and 50 mm — so a run can be trimmed to the millimetre without cutting glass on site.
The datasheet also assigns a type letter to each length: the 5, 15 and 25 mm spacers are Type A, and the 50 mm spacer is Type B.
Features
Built into every unit.
- Makes up small increments in line length — 5, 15, 25 and 50 mm
- DN 15, 25, 40 and 50
- Type A up to 25 mm, Type B at 50 mm
- Borosilicate 3.3, same bore and end detail as the pipe sections
Benefits
Why it earns its place in the line.
- Completely inert to almost all process media — no metal pick-up and no contamination of the batch
- Full visibility of the process along the whole line
- Smooth, non-wetting bore that resists fouling and cleans easily
- Excellent thermal shock resistance from borosilicate 3.3
- Modular flanged construction — sections can be swapped without cutting or welding
Applications & industries
Where it is specified.
Typical applications
- Trimming a glass run to its as-built dimension
- Filling the gap left when a valve or instrument is removed
- Adjusting for gasket and flange stack-up
- Commissioning make-up between fixed equipment
Industries served
- Chemical processing
- Pharmaceutical
- Fine chemicals & dyes
- Food & beverage
- Water & effluent treatment
- Distillation & solvent recovery
- Research & pilot plant
Technical data
Specification for Spacer.
Figures below are for this product only — every item in the range carries its own dimension table.
| Product type | Glass spacer |
|---|---|
| Material | Borosilicate 3.3 |
| Nominal bore range | DN 15 to DN 50 |
| End connection | Beaded pipe ends with backing flanges and PTFE-envelope gaskets |
| Flange drilling | See the drilling table — BS 10 Table E, BS 10 Table F and ASA drilling available |
| Pressure rating | Not published on the component datasheet — confirm with us for your duty |
| Temperature rating | Not published on the component datasheet — confirm with us for your duty |
| Dimensional standard | As per the Lata Scientific component datasheet |
| Catalogue reference | LSSS series, e.g. LSSS1/25 = DN 25 × 25 mm |
| Available lengths | 5, 15, 25 and 50 mm |
| Length L | Type | DN 15 | DN 25 | DN 40 | DN 50 |
|---|---|---|---|---|---|
| 5 | A | LSSS07/5 | LSSS1/5 | LSSS1.5/5 | LSSS2/5 |
| 15 | A | LSSS07/15 | LSSS1/15 | LSSS1.5/15 | LSSS2/15 |
| 25 | A | LSSS07/25 | LSSS1/25 | LSSS1.5/25 | LSSS2/25 |
| 50 | B | LSSS07/50 | LSSS1/50 | LSSS1.5/50 | LSSS2/50 |
All dimensions in mm, transcribed exactly from the component datasheet.
FAQ
Questions we are asked about this item.
The datasheet marks the 5, 15 and 25 mm spacers as Type A and the 50 mm spacer as Type B. Quote the type with the catalogue reference when ordering.
Yes — see the PTFE spacer, which covers 5, 10, 15 and 20 mm in the same bores.
Enquiry
Tell us your line size — we'll confirm the spec.
Send the bore, the media, the temperature and pressure, and the flange standard you work to. Drawings and custom sizes welcome.
Not sure which spec fits your process?
Send your requirement — media, temperature, pressure, dimensions — and we'll recommend the right product or fabricate it.